Articles on Technology, Health, and Travel

Factorio boiler steam engine ratio of Technology

There is a mismatch of information between the boil.

Re: Water Supply Problem Steam Setup. by Xterminator » Thu Jul 02, 2015 5:00 pm. As you probably know, the ideal ratio for a steam engine setup is 1 pump, 13 (or 14) boilers, and 10 steam engines. Using 13 boilers will run it at 99% efficiency, 14 will run it at 100%. Problem is, as Fish pointed out, you can't just like multiply that by 2 or 3 ...No amount of solar panels can replace a boiler and two engines. During night solar panels produce zero power while a boiler and two engines would produce 1.8 MW. Now, if you don't remove the boiler and two engines, then 30 solar panels would replace the boiler+two engines during the day. During the night the boiler+two engines would still run.Connecting the Steam Engine. It's time to connect the steam engine after assembling the boiler and offshore pump. Position the steam engine next to the boiler, making sure that the side with the steam icon faces the boiler. This connection enables the boiler to send steam to the steam engine. It is crucial to remember that by connecting ...If enabled, the main changes are: new boilers will eat through fuel a lot faster than the ones enabled by default in this mod, able to heat up water faster, or with less boilers, and a MK4 is 60% more efficienct than a MK1. new steam engines will consume more steam to produce more power, instead of being insanely more efficient each step and ...Steam engines only generate as much power as needed. If only 450 kW of power is required, they'll run at half performance. If nothing is drawing power, they won't run at all. Machines need to be connected to the same power grid in order to receive power from the engines. If your machines don't get any power, make sure they're connected properly.Factorio Forums. www.factorio.com. Quick links. Wiki; Active topics; FAQ; Board index. Support. Gameplay Help. Furnaces and steam engines ... 5 posts • Page 1 of 1. Teodorp99 Manual Inserter Posts: 1 Joined: Wed Aug 30, 2017 10:23 am. Furnaces and steam engines. Post by Teodorp99 » Wed Aug 30, 2017 10:27 am. So i have my setup here but i'm ...In this case, click on a section of pipe and the little info window should show you what's in the pipe. If it's more than one fluid, empty out the one that doesn't belong by hitting the little trash icon. Boiler needs fuel. Put some trees or coal into it.1.5 Pump : 17 boilers :13 Steam engines - better ratio, but you have to split up one pump and therefor the setup is more complicated. You have to care about pipe length a little. (2x (1 Pump : 14 boilers)) : 20 Steam engine - this one can be more compact but is hard to set up.Feb 27, 2019 · It's the exact same as it was before. Instead of the boilers getting half the energy of the coal, now the boilers get 100% of the energy, but coal only has half as much as it did in the last update. Efficiency is a measure of how much energy is converted to what you want it to be. 50% efficiency means only half of the energy you put in is being ...Do you know how to drain a radiator? Find out how to drain a radiator in this article from HowStuffWorks. Advertisement Many homes are heated by using a boiler. The boiler heats wa...Steam engine uses 30 steam/second. Boiler:engine ratio is 1:2. Result: 1 pump 20 boilers 40 steam engines. Input: A little bit more than half a yellow belt of coal. Output: 35.8 MW (36.0 MW optimal) The layout of the …If you feed boiler-output steam into the heat exchangers, you can get a perfect-ratio 58 MW from 1 reactor, 4 heat exchangers, 10 boilers, and 10 turbines, which is easily scaled to any of the other Reactor Equivalent Unit setups.Showing 1 - 7 of 7 comments. <unknown> Sep 9, 2017 @ 11:19pm. 1:2 ratio so 0.5 boiler for a steam engine. #1. Lawlzer Sep 9, 2017 @ 11:43pm. 1:20:40 in .15. 1:10:14 in 0.14. so in 0.15 you want 1water pump, 20 boilers and 40 steam engines. Easiest way is just a line of pipes with boilers coming out the side, with 2 steam engines per boiler.One boiler is capable of producing 60 steam per second. 1 steam is made from 1 water, the rest is passed through. Offshore pumps can produce 1200 units of water per second. 1200/60 = 20 One steam engine can use 30 steam per second. 1200/30 = 40 Q.E.D.Apr 24, 2017 · But now I'm completely lost... has anyone figured out the new optimum boiler to steam engine ratio? Right now it looks like an offshore pump can support 40 steam engines, but that's all I can figure out. I'd appreciate the help, just started a new map.With the changes has the ratio of 1 pump, 14 boilers, and 10 steam engines changed? EDIT: The new ratio is 1 pump, 20 boilers, 40 steam engines.A single red belt of ore can feed 48 steel furnaces. This makes for easy upgrading of smelting setups. Iron ore to steel is 1:1 for furnaces. 1:20:40 (:18) for offshore:boiler:steam engine (:electric mining drill). Note the 1:2 ratio for boiler to steam engine. mining drill only applies before mining prod.that noise I found the argument that the current balancing of Factorio would make that way of storing energy too powerful. The issue here boils down to. steam engines being 100% efficient, while they are not in reality, boilers are not 100% efficient, while they basically are in reality, and not having heat loss due to dissipation implemented.And finally, an ongoing bug is causing the ratio of boilers/engines to be slightly lower than 1:2. As such, any 1:2 steam engine setup, including this one, will eventually run out of steam. After approximately 20 minutes, the steam buffers in the boilers and engines will deplete in this setup, causing average power production to drop by roughly ...A hundred people have probably arrived independently at different aspects of these designs, such as pump:engine ratio, boiler:engine ratio, how to make compact, how to use cheap low tech.Best boiler to Steam ratio now, is it still 15 is the best for multiple gnerators?Reading the content of the top-right chest and connecting it with the power-switch will let you connect the power to your steam engines when the power in the accumulator drops to 20% and disconnect the switch when the power hit 100%. (obviusly you can use any % of power and any item in the chest).I made infinity energy with steam engine. In this house we obey the law of thermodynamics. This is kinda accurate on how real life electricity is created with steam in a Rankine Cycle. Factorio system of boiler+engine, being the engine a …www.factorio.com. Quick links. Wiki; Active topics; FAQ; Board index. Support. Gameplay Help. Furnaces and steam engines. Don't know how to use a machine? Looking for efficient setups? Stuck in a mission? 5 posts • Page 1 of 1. ... Furnaces and steam engines. Post by Bauer » Wed Aug 30, 2017 12:34 pm.The ratio of engines to boilers is the boiler consumption * boiler efficiency / engine output The ratio of engines to offshore pumps is 1200/s / fluid consumption per engine. mk1 is 40, mk2 is 32, and mk3 is 26.667, which I rounded to 24. For the engines to run at max efficiency, they need the boilers to go hot enough, and most combinations dont.Re: Boiler / steam engine ratio Post by boro » Sun Jun 15, 2014 2:58 pm One pump can support 10 engines and you need 14 boilers for that (or 13 for 99% max load)Water goes into either of the long ends of the boiler. Steam comes out the side. DO NOT mix water and steam, or they will continually get blocked up. Connect a water inlet to the offshore pump. Connect the side outlet for steam to the steam engine. Don't join these pipe networks together.The Accumulator stores a limited amount of energy when available production exceeds demand, and releases it in the opposite case. The accumulator can store up to 5 MJ of energy. Its maximum charge/discharge rate is 300 kW. If connected to a circuit network, an accumulator will output its level of charge, as an integer from 0 to 100, to a specified signal.Where typical ratio for steam power is 1:20:40 (pump:boiler:engine), it would be possible to enhance it to 1:20:80 for example and a few fluid tanks connected to those steam engines. While it would be almost twice as large build, it would be able to handle peak power demand like laser turrets much better.anyone know how many boilers you can fit to a steam engine?At average atmospheric pressure, the expansion ratio between water in its liquid form and steam is 1:1700. This means that under ideal conditions, 1 part of liquid water expands to...Boilers can only boil steam to 235 degrees, but steam engines require 275.With the standard 13:10 boiler:steam engine ratio, effectively ~100% of the fuel energy consumed by boilers is turned into electricity. Even if steam engines were implemented as a perfect Carnot cycle, then for hot temperature 100C~=373K and cold temperature 15C=~288K, their energy conversion efficiency would be around (1 - (288/373)) ~= 23%.When power demand goes over 1.8MW, more engines will turn on and at higher outputs, consuming more steam until the spare fluids in the pipes and engine reserves are consumed, until only the 60 steam/second the boiler is what's in the system, being consumed immediately by 2-4 engines splitting that 60 between them while the rest of the engines ...Here are the ratios I came found. It shows the amount of boilers per steam engine, aka 7 boiler mk1 to 5 steam mk2. You can have up to 10 Steam engines mk1, 7 Steam engines mk2, and 5 Steam engines on mk3 using the offshore pump. steam 1steam 2steam 3. boiler 11.402.002.80. boiler 21.001.432.00. boiler 30.801.141.60.Showing 1 - 7 of 7 comments. <unknown> Sep 9, 2017 @ 11:19pm. 1:2 ratio so 0.5 boiler for a steam engine. #1. Lawlzer Sep 9, 2017 @ 11:43pm. 1:20:40 in .15. 1:10:14 in 0.14. so in 0.15 you want 1water pump, 20 boilers and 40 steam engines. Easiest way is just a line of pipes with boilers coming out the side, with 2 steam engines per boiler.In 5dim the numbers change is all, such as effectivity = 0.75 when looking at prototypes/boilers-2.lua in the mod file. Just use the new numbers in the math to calculate the best ratio.The burner mining drill is the first type of drill accessible to the player. It burns fuel to mine the ore underneath the 2×2 area it is placed on. It mines about 7 items per single unit of coal used to fuel it, producing 0.25 items/s for copper ore, coal, iron ore or stone. Burner miners create a lot of pollution per item.It's the exact same as it was before. Instead of the boilers getting half the energy of the coal, now the boilers get 100% of the energy, but coal only has half as much as it did in the last update. Efficiency is a measure of how much energy is converted to what you want it to be. 50% efficiency means only half of the energy you put in is being ...14 votes, 14 comments. 350K subscribers in the factorio community. Community-run subreddit for the game Factorio made by Wube Software. ... In 0,15, the ratio is 1:20:40, or 20 boilers per offshore pump and 2 steam engines per boiler. Reply reply SirNoName • So I'm just getting back into factorio after a long (several month) hiatus, and ...Here are the ratios I came found. It shows the amount of boilers per steam engine, aka 7 boiler mk1 to 5 steam mk2. You can have up to 10 Steam engines mk1, 7 Steam engines mk2, and 5 Steam engines on mk3 using the offshore pump. steam 1steam 2steam 3. boiler 11.402.002.80. boiler 21.001.432.00. boiler 30.801.141.60.1 pump = 20 boiler with 2 steam engine for 1 boiler. More boiler and they will not have enough water, nearly no water in fact. More engine per boiler make the third engine and those after it not working at all. 1 pump support enough steam engine (40) for 38MW !You raise an interesting point that accus are a big oil sink in direct competition with using said oiil for powering steam engines during the night. 10 crude oil yield 1/4.5/5.5 cracked to 0/5.25/5.5. For batteries, this can be cracked further to 9 gas. For power, this yields 5.25 + 2.75 = 8 soild fuel.Where typical ratio for steam power is 1:20:40 (pump:boiler:engine), it would be possible to enhance it to 1:20:80 for example and a few fluid tanks connected to those steam engines. While it would be almost twice as large build, it would be able to handle peak power demand like laser turrets much better.what is the best ratio of boilers to steam engine? 1-14-10. 1 offshore pump to 14 boilers to 10 steam engines. Just as an addendum, this ratio comes from the fact that a boiler's power output is 390kW, while a steam engine's is 510kW (both numbers available on the in-game tool tip). This gives the optimal ratio as 510/390 = 1.3077 (approximately).Mazian Jul 17, 2016 @ 12:08pm. Output will scale with demand, up to the maximum potential output of the steam engine. There is nothing wrong with 12 steam engines and 1.1 MW output-- because 1.1 MW is your maximum demand at the time you took the screenshot. It's only a problem with demand exceeds maximum capacity. #1.The gold-silver ratio is measure of how many ounces of silver it takes to buy an ounce of gold. The gold-silver ratio is measure of how many ounces of silver it takes to buy an oun...what is the best ratio of boilers to steam engine? 1-14-10. 1 offshore pump to 14 boilers to 10 steam engines. Just as an addendum, this ratio comes from the fact that a boiler's power output is 390kW, while a steam engine's is 510kW (both numbers available on the in-game tool tip). This gives the optimal ratio as 510/390 = 1.3077 (approximately). Hi !! I try to find the ratio between the number oFactorio Forums. www.factorio.com. Quick liBob's improves on this by higher tier boilers that a

Health Tips for Costco management careers

Best boiler to Steam ratio now, is it still 15 is the be.

40 steam engines. Input: A little bit more than half a yellow belt of coal. Output: 35.8 MW (36.0 MW optimal) The layout of the boilers allows for inserters inbetween them. However, the new boilers use a LOT more fuel than the old ones, to the point where inserters cannot keep up. A yellow inserter can only draw enough coal from the belt to ...Even though all fluids in the game have a temperature value, it is generally the default 15°C. Energy, whether harnessed from fuel in boilers, or from nuclear power through heat exchangers, can be used to turn water to steam, being a liquid form of work. Steam holds energy at a ratio of 0.2 kJ per °C per unit.thanks. or you could just add a single pipe between the engines and have a non steel setup for early game without any throughput issues whatsoever :) Two ways this works: Boiler - Engine - Engine, Boiler - Engine - Pipe - Engine. You have to add one pipe for every 2 boilers, but it can be added either between boilers or between engines.Steam engine power. Each steam engine needs 0.5 boilers when running at full capacity. One offshore pump can supply 20 boilers and 40 steam engines. The above ratio can be calculated from information available in-game: One boiler consumes 1.8MW of fuel and produces energy stored in steam at 100% efficiency.A steam boiler can convert up to 60 units of water into steam per second, providing 1.8MJ of steam (at 165 °C). A steam boiler consumes 1.8MJ of fuel per second. A steam engine can convert 30 units of steam (at 165 °C) per second into 0.9MW of electric power. 40 steam engines will provide 36MW of power.Hi !! I try to find the ratio between the number of coal drill and the new boiler because i just start a new map this morning and i need to find a lot of coa…Sep 7, 2023 · Originally posted by knighttemplar1960: You are getting into messy math territory. Boilers use carbon based fuel to produce 60 steam per second at a temperature of 165 C. 2 steam engines use up exactly 1 boiler's worth of 165 C steam (30 steam per second each) to produce 900 kw each. Turbines use 60 units of 500 C steam (produced by nuclear ...3) Add a few solar cells and accumulators to the electrical network for the inserters. 4) For large plans you can even do multiple stages. First a mini plant (1-2 steam engines) with burner inserter or solar powered inserter. Add a buffer chest so it always has a backup of fuel.Find blueprints for the video game Factorio. Share your designs. Search the tags for mining, smelting, and advanced production blueprints. ... steam-engine: 69: transport-belt: 40: burner-inserter: 40: boiler: 24: small-electric-pole: 20: pipe: 8: small-lamp: Extra Info. steam-engine: Details Standard boiler power plant. This one uses burner ...Some powerplants have a single steam engine, which can be started on batteries or even a hand powered generator. Once it's running, it can supply the 5 MW needed to start the high efficiency steam engines with filtered chimneys. When the high efficiency steam engines start supplying, the low efficient and unfiltered starter engines can shut down.used to be 1 pump to 14 boilers to 10 steam engines. Now a pump supplies 1200 units/s of water, and a steam engine consumes 30 units/s of steam. And water seems to be converted to steam at a 1/1 ratio. So does that mean we can now run 40 steam engines off a single offshore pump ? (excluding a storage system for either water or heated steam).From the looks of it, your boiler to steam engine ratio is 1/1; you have far too few boilers for that quantity of steam engines. Rather than 48 boilers, you need something closer to 68. Even if you were supplying enough water, the steam engines would not be operating at 100% max efficiency, wasting much of the gains a steady would supply would ...It is currently set up to a 1 boiler to 1 Steam Turbine ratio, with an adequate water supply. The "Fluid Consumption" stays at around (30/60), but my old steam engines stay at around (5/30) w/ full "Available Performance" so I don't think that matters too much. Any suggestions to try to get the "Available Performance" to full would be great ...Jan 19, 2017 · With the standard 13:10 boiler:steam engine ratio, effectively ~100% of the fuel energy consumed by boilers is turned into electricity. Even if steam engines were implemented as a perfect Carnot cycle, then for hot temperature 100C~=373K and cold temperature 15C=~288K, their energy conversion efficiency would be around (1 - (288/373)) ~= 23%.The burner mining drill is the first type of drill accessible to the player. It burns fuel to mine the ore underneath the 2×2 area it is placed on. It mines about 7 items per single unit of coal used to fuel it, producing 0.25 items/s for copper ore, coal, iron ore or stone. Burner miners create a lot of pollution per item.Find blueprints for the video game Factorio. Share your designs. Search the tags for mining, smelting, and advanced production blueprints. ... steam-engine: 69: transport-belt: 40: burner-inserter: 40: boiler: 24: small-electric-pole: 20: pipe: 8: small-lamp: Extra Info. steam-engine: Details Standard boiler power plant. This one uses burner ...Ratio is now 1 new boiler to 2 steam engines. Steam engines each produce almost twice as much power each as before.If enabled, the main changes are: new boilers will eat through fuel a lot faster than the ones enabled by default in this mod, able to heat up water faster, or with less boilers, and a MK4 is 60% more efficienct than a MK1. new steam engines will consume more steam to produce more power, instead of being insanely more efficient each step and ...This blueprint is part of the "Base-in-a-Book" Tutorial series by Nilaus: https://goo.gl/rGdWWV. Base-in-a-Book 2. Steam Power. 2. Steam Power (4 Boilers+8 Engines) If you put a single straight pipe between each steam engine, you can fit the power line in between the engines themselves. That allows you to fit the full 20 boilers that the pumps ...I just wanted to share the 3:42:30 alternative to 1:14:10. Same power output per engine, same ratio (scaled up), rather the design can save you some space if you're stacking one engine line on top of another along a flat shore, which if you're working at a scale of needing to blueprint 100 steam engine at a time may be the case for you.40 steam engines. Input: A little bit more than half a yellow belt of coal. Output: 35.8 MW (36.0 MW optimal) The layout of the boilers allows for inserters inbetween them. However, the new boilers use a LOT more fuel than the old ones, to the point where inserters cannot keep up. A yellow inserter can only draw enough coal from the belt to ...If you're looking for a way to draw more attention to the crucial elements in your photographic composition, the Fibonacci Ratio offers a way to direct your viewers eye to the crit...15 coal/s burnt in boilers to steam the engines yields 60 MW of power. So that you get 58MW with 15 units of coal mined per second. Then I have opened the Helmod and calculated the CLF to consume 15 coal/s and use coke for steam. The heavy oil prodcut gets cracked to light oil and then all the LO and petroleum gas get condensed into the coke.The 7% means your boliers will be 7% under-utilized. In practice it means if your steam engines are working at their full capacity, the last boiler would turn on and off - 510*10 - 390*13 = 30 So the last boiler would only be on 30/390 = 7.7% of the time.Boilers now output steam to the sides. In 0.15 you can't have them in-line with steam engines. Ratio is 1 pump, 20 boilers, 40 steam engines. Actually it's 1 boiler for each Steam engine. Boilers say they got 1.8MW power consumption, but at 50% efficiency, so the output is only 900kw (same as steam engine use). It's 1 boiler per 2 steam engines.Factorio Forums. www.factorio.com. Quick links. Wiki; Active topics; FAQ; Board index. General. General discussion. 0.15 boiler ratio? Post all other topics which do not belong to any other category. 31 posts 1; 2; Next; Forzberg Burner Inserter Posts: 9 Joined: Wed Feb 22, 2017 2:46 pm. 0.15 boiler ratio?A debt-to-income ratio (DTI) is a tool lenders use to dKeep in mind the 1:4:7 ratio is rounded, and for huge rea

Top Travel Destinations in 2024

Top Travel Destinations - In Bob's Power, the ratio of eng

Adds a higher tier of boiler and steam engine which are more efficient Content Mod category: Content Mods ... Factorio version: 1.1 Downloaded by: 3.12K users. Adds advanced versions for boilers and steam engines …Each steam engine needs 0.5 boilers when running at full capacity. One offshore pump can supply 20 boilers and 40 steam engines. The above ratio can be calculated from information available in-game: One boiler consumes 1.8MW of fuel and produces energy stored in steam at 100% efficiency.So the "perfect ratio" coal power plant takes just over half a yellow belt, which is just terrible if you're really squeezing your coal source hard. I submit the correct ratio is: 2 offshore pumps : 34 boilers : 67 steam engines : 1 yellow belt of coal = 60.3 MW. Noting the following:A turbine can use 60 liquid/second, a steam engine can use 30/s. In terms of power produced, 1 boiler can supply 1 turbine or 2 steam engines at most, and the electricity generated is equal - as is the chemical fuel and water consumed in the process. Alternatively, you can generate 900Kw of electricity from 500 degree steam with a simple steam ...With the standard 13:10 boiler:steam engine ratio, effectively ~100% of the fuel energy consumed by boilers is turned into electricity. Even if steam engines were implemented as a perfect Carnot cycle, then for hot temperature 100C~=373K and cold temperature 15C=~288K, their energy conversion efficiency would be around (1 - (288/373)) ~= 23%.So to run a steam engine @ 510kw needs 1020kw of boiler. Each boiler is 780kw/50%=390kw in your steam engine. These numbers are the reasoning behind the commonly used 1:14:10 setup. 1 offshore pump = 60 units/second. 10 steam engines @ 6 units/second each = 60 units. 14 boilers @ 390kw each = 5460kw. 10 steam @ 510kw = 5100kw. Thats 360kw extra.From the looks of it, your boiler to steam engine ratio is 1/1; you have far too few boilers for that quantity of steam engines. Rather than 48 boilers, you need something closer to 68. Even if you were supplying enough water, the steam engines would not be operating at 100% max efficiency, wasting much of the gains a steady would supply would ...From the looks of it, your boiler to steam engine ratio is 1/1; you have far too few boilers for that quantity of steam engines. Rather than 48 boilers, you need something closer to 68. Even if you were supplying enough water, the steam engines would not be operating at 100% max efficiency, wasting much of the gains a steady would supply would ...Oct 3, 2017 · I believe the number is correct but the conclusion is wrong, 1 mine able to power 1.1667 boilers, i set up 1 boiler, 2 steam engines powering 21 electric mining drill and 1 of the drill direct output coal into the boiler, the rest output to chest, constantly over draining power from the setup, the coal in the boiler still increasing.Here are the ratios I came found. It shows the amount of boilers per steam engine, aka 7 boiler mk1 to 5 steam mk2. You can have up to 10 Steam engines mk1, 7 Steam engines mk2, and 5 Steam engines on mk3 using the offshore pump. steam 1steam 2steam 3. boiler 11.402.002.80. boiler 21.001.432.00. boiler 30.801.141.60.Steam production i/s is on the Wiki Likewise for consumption of steam for steam turbines and steam engines. Example: 14 Heat exchangers, 24 steam turbines Boilers: 14 * 103.0927835 steam produced/water consumed -> 1443,298969 i/sec steam/water Steam Turbines: Divided by boiler consumption 60 i/sec -> 24.0549828167 steam turbines needed Pipes:And finally, an ongoing bug is causing the ratio of boilers/engines to be slightly lower than 1:2. As such, any 1:2 steam engine setup, including this one, will eventually run out of steam. After approximately 20 minutes, the steam buffers in the boilers and engines will deplete in this setup, causing average power production to drop by roughly ...Best boiler to Steam ratio now, is it still 15 is the best for multiple gnerators?I have not played vanilla in a while, what is the current boiler to steam engine ratio? Login Store Home Discovery Queue Wishlist Points Shop News StatsHot Steel Boiler. A small game mod to add a new fueled boiler outputing hotter steam with a matching. upgraded steam engine. The new Steel Boiler, unlocked after Advanced Material Processing, generates 350°C. steam at 60/s which when paired with the matching Steel Engine will generate 4.02MW. of electricity at a 1:1 ratio.Find blueprints for the video game Factorio. Share your designs. Search the tags for mining, smelting, and advanced production blueprints. ... 20/40 boiler/steam engine perfect ratio for one offshore pump. Burner inserter in the event of a power failure. Easily repeatable. Stats: 136 Transport belt; 40 Steam engine; 20 Boiler;I just wanted to share the 3:42:30 alternative to 1:14:10. Same power output per engine, same ratio (scaled up), rather the design can save you some space if you're stacking one engine line on top of another along a flat shore, which if you're working at a scale of needing to blueprint 100 steam engine at a time may be the case for you.Boiler consumes 1.8MW, but is 50% efficient, so should produce 900KW in steam. Which is exactly one steam engine. If water consumption is also 50% efficient, a boiler eats 60/sec in water (steam engines eat 30/sec). Pump produces 1200, so you could do 50 boilers per pump if my math's correct. And 1:1 on steam engines per boiler, so 50 steamers too. It's the exact same as it was before.